Calculadora del tamaño del generador de vapor

Enter your shower's dimensions, ceiling height and wall material. The calculator applies ThermaSol's and Mr. Steam's published sizing rules and recommends a generator from each brand.

Calculate Your Generator Size

Preferred Brand ?
Shower Enclosure Dimensions
OR
?
?

Large glass walls or a glass ceiling: Mr. Steam says large glass areas call for a larger generator but gives no figure, so call us before you order. ThermaSol's rule does not change for glass.

Steam shower generator
Your Generator
Recommendation Awaits
Recommended Generator Size

Recommended Generators For Your Shower

Questions about your shower, or a result near a model's limit? Call us at (888) 833-2305 before you order.

Steam Generator Sizing Rules: ThermaSol and Mr. Steam

ThermaSol and Mr. Steam start from the same measurement, the shower's length, width and height in feet, but they adjust it differently and rate their generators for their own methods. Compare the model each brand recommends for your shower rather than comparing cubic-foot ratings across brands.

Factor ThermaSol PRO Series III Mr. Steam MS, MS Super and MAX
Ceramic or porcelain tile No adjustment No adjustment
Natural stone, marble, shale, glass block or concrete No adjustment Add 50%
Acrylic or fiberglass No adjustment; the walls must be steam rated by their manufacturer Subtract 40%
Large glass areas No adjustment A larger generator; no figure given
9 ft ceiling Size up one generator Add 15% to the wall-adjusted volume
10 ft ceiling Size up two, or confirm with ThermaSol Add 30% to the wall-adjusted volume
Over 10 ft Not recommended by ThermaSol Outside the published rules (10 ft maximum)

ThermaSol's PRO Series III page states that wall materials do not affect generator size, and its installation manual says the number in each model name is the maximum capacity in cubic feet with a ceiling of 8 feet or less. Mr. Steam's installation manuals for the MS and MS Super series and for the MAX series use the same worksheet: adjust the room volume for the wall material, then add 15% of that adjusted volume for each foot of ceiling above 8 feet, to a 10 ft maximum, and compare the total with the chart. The calculator counts a partial foot of ceiling height as a full foot, so an 8.5 ft ceiling is sized as 9 ft.

For acrylic or fiberglass enclosures, ThermaSol says the walls must be steam rated by their manufacturer and that it recommends specific generators for acrylic modules. Mr. Steam's worksheet subtracts 40%, while notes in the same manuals give other acrylic rules (the next lower-rated MS model, or 15% off the room volume for the MAX series), so we confirm acrylic sizing with you before you order.

Example: a 4 x 5 ft shower with a 9 ft ceiling and marble walls holds 180 cubic feet. ThermaSol's rules call for the PROIII-240 by volume, plus one size for the ceiling: the PROIII-395 (11 kW). Mr. Steam's rules add 50% for marble (270 cubic feet), then 15% of that for the ceiling (310.5 cubic feet): the MSSUPER1R (10 kW).

ThermaSol PRO Series III Sizing Chart

Model Power Maximum shower volume Current draw
PROIII-846 kW84 cu ft28 A
PROIII-1408 kW140 cu ft37 A
PROIII-24010 kW240 cu ft46 A
PROIII-39511 kW395 cu ft55 A
PROIII-57515 kW575 cu ft69 A
PROIII-75020 kW750 cu ft92 A
PROIII-120024 kW1,200 cu ft110 A

Maximum volumes assume a ceiling of 8 ft or less. Current draw as listed in ThermaSol's PRO III installation manual for 208 to 240 V single-phase service.

Mr. Steam Sizing Chart

Model Series Power Adjusted room volume Current draw at 240 V
MS90RMS5 kWUp to 71 cu ft21 A
MS150RMS6 kW72 to 107 cu ft25 A
MS225RMS7.5 kW108 to 161 cu ft32 A
MS400RMS9 kW162 to 257 cu ft38 A
MSSUPER1RMS Super10 kW258 to 339 cu ft42 A
MSSUPER2RMS Super12 kW340 to 411 cu ft50 A
MSSUPER3RMS Super15 kW412 to 482 cu ft63 A
MX4RMAX20 kW483 to 678 cu ft84 A
MX5RMAX24 kW679 to 822 cu ft100 A
MX6RMAX30 kW823 to 964 cu ft125 A

The adjusted room volume is the shower's volume after Mr. Steam's wall and ceiling adjustments. Ranges and current draw come from the specification charts in Mr. Steam's MS and MS Super and MAX installation manuals.

How to Measure Your Steam Shower Size

1. Measure the inside of the enclosure: width, depth and ceiling height, in feet or inches. The calculator multiplies them to get the volume in cubic feet. If you already know the volume, enter it directly and set the ceiling height.

2. Set the ceiling height: ThermaSol sizes up for 9 and 10 ft ceilings, and Mr. Steam adds 15% per foot above 8 ft. If you enter a height in the dimensions, the calculator sets this for you.

3. Choose the main wall material: it changes the Mr. Steam result only. If the shower has large glass walls or a glass ceiling, call us, because Mr. Steam gives no figure for them.

4. Calculate: you will see one ThermaSol model and one Mr. Steam model, or a single brand if you selected one. Each recommendation links to the product page, where you can choose the control, steam head and finish. Use Get Pricing to request a quote.

Electrical Requirements

ThermaSol: PRO Series generators require a 208 to 240 V single-phase power supply with a dedicated breaker. ThermaSol's manual calls for copper wire rated for at least 90°C and requires a licensed electrician for all electrical work.

Mr. Steam: the MS and MS Super manual calls for a separate circuit breaker, both of its residential manuals call for a power disconnect within sight of the generator, and Mr. Steam bases wire sizes on copper conductors rated for at least 90°C. Mr. Steam makes the MS and MS Super series for 240 V or 208 V single-phase service and other voltages and phases, and the MAX series for 208 or 240 V, single or three phase.

Current draw by model is in the sizing charts above. Have a licensed electrician confirm your panel capacity and size the circuit before you order.

Where the Generator Goes

ThermaSol: up to 50 feet from the shower, typically in a closet, vanity cabinet, climate-controlled attic or basement, in a dry, non-combustible, well-ventilated space with 6 inches of clearance around the generator. Never install it inside the steam room.

Mr. Steam (MS and MS Super): install the generator as near as practical to the steam room, typically in a closet, vanity cabinet, heated attic or basement, with at least 12 inches clear at both ends and on top. Never install it inside the steam room, outdoors or in an unheated attic.

Mr. Steam (MAX): a heated attic or basement, in a room with ventilation. Never install a MAX generator inside a vanity or other small enclosed space, or under the steam room bench. Mr. Steam calls for at least 18 inches clear on the left side and 21 inches on top.

Mr. Steam's sizing charts allow up to 60 feet of insulated steam piping between the generator and the steam room.

Steam Generator Brands We Carry

ThermaSol PRO Series III

Seven generators from 6 to 24 kW, rated for showers up to 84, 140, 240, 395, 575, 750 and 1,200 cubic feet. ThermaSol lists FastStart, which it describes as steam in seconds, not minutes, a self-cleaning PowerFlush system and patented Smart Steam, which it says delivers precise temperature control and steady steam, as PRO Series III features. It also lists a SteamVection kit and a stainless steel drain pan as included.

ThermaSol gives PRO Series generators a two-year limited in-home warranty, followed by a factory limited warranty that replaces defective parts for the life of the product for the original purchaser.

Mr. Steam MS, MS Super and MAX

Ten generators from 5 to 30 kW: the MS series (5 to 9 kW), MS Super (10 to 15 kW) and MAX (20 to 30 kW). Each comes in a standard version or with factory-installed Express Steam, which keeps the water in the tank warm so steam comes up sooner. The AutoFlush system, which drains the generator about two hours after each use, and a Wi-Fi module for control from a smartphone app are optional.

Mr. Steam's manuals say its generators are designed, engineered and assembled in the USA. Mr. Steam gives its residential generators a limited lifetime warranty in the US and Canada: in-home service, parts and labor for two years, then parts for the life of the generator.

Steam Generator Sizing FAQ

Multiply your shower's length, width and height in feet, then apply each brand's rules. A 3 x 4 x 8 ft tiled shower holds 96 cubic feet: ThermaSol's rules call for the PROIII-140 (8 kW) and Mr. Steam's for the MS150R (6 kW). The calculator above applies both sets of rules, including the ceiling height and, for Mr. Steam, the wall material.
ThermaSol and Mr. Steam publish different sizing rules and rate their generators for those rules. ThermaSol sizes on volume and ceiling height only, while Mr. Steam also adjusts for the wall material. Compare the model each brand recommends, not cubic-foot ratings across brands. Our ThermaSol vs Mr. Steam comparison covers the other differences.
Mr. Steam's installation manuals use a four-step worksheet: multiply the length, width and height; add 50% for natural stone, marble, shale, glass block or concrete, subtract 40% for acrylic or fiberglass, or leave ceramic or porcelain tile unchanged; add 15% of that adjusted volume for each foot of ceiling above 8 ft, to a 10 ft maximum; then choose the model whose range covers the total. A 180 cubic foot marble shower with a 9 ft ceiling comes to 310.5 cubic feet, which calls for the MSSUPER1R (10 kW).
For ThermaSol, no: its PRO Series III page states that wall materials do not affect generator size, although its manual says acrylic walls must be steam rated by their manufacturer. For Mr. Steam, yes: its manuals add 50% for natural stone, marble, shale, glass block or concrete, subtract 40% for acrylic or fiberglass, and make no adjustment for ceramic or porcelain tile. Mr. Steam also says large glass areas call for a larger generator, without giving a figure.
ThermaSol says to size up one generator for a 9 ft ceiling, and two for a 10 ft ceiling or to confirm with its team, and it does not recommend a ceiling over 10 ft. Mr. Steam's manuals add 15% of the wall-adjusted volume for each foot above 8 ft, up to a 10 ft maximum. The calculator counts a partial foot as a full foot. For a ceiling above 10 ft, call us before you order.
ThermaSol allows up to 50 feet between the generator and the shower. For MS and MS Super generators, Mr. Steam recommends a closet, vanity cabinet, heated attic or basement as near as practical to the steam room, with up to 60 feet of insulated steam piping. MAX generators go in a heated, ventilated attic or basement, never in a vanity or other small enclosed space. Neither brand's generator may be installed inside the steam room.
A dedicated circuit. ThermaSol PRO Series generators require a 208 to 240 V single-phase supply with a dedicated breaker and draw from 28 A (PROIII-84) to 110 A (PROIII-1200). Mr. Steam generators draw from 21 A (MS90R) to 125 A (MX6R) at 240 V. Have a licensed electrician size the circuit.
The control is not included: each generator requires a compatible control, which we quote with the generator together with the steam head. ThermaSol lists a SteamVection kit and a stainless steel drain pan as included with the PRO Series III, and each Mr. Steam control comes with a steam head. On each generator's product page, our configurator lets you choose the control, steam head and finish and sends the build to us for a quote.

Ready to Plan Your Steam Shower?

Send us your shower's dimensions, ceiling height and wall material, and the generator you are considering. We will quote the generator together with a compatible control and steam head.