{"product_id":"delta-commercial-steam-boiler-package","title":"Delta Commercial Steam Boiler Package","description":"\u003ch2\u003eDelta Commercial Steam Boiler Package\u003c\/h2\u003e\n\u003cp\u003eThe Delta Commercial Steam Boiler Package is a turnkey, commercial-grade steam system engineered for continuous, all-day operation in spas, hotels, gyms, health clubs, and recovery facilities. Available in eight outputs from 9 to 48 kW, it sizes steam rooms from compact treatment suites up to 2,000 cubic feet — and a single boiler can drive a second room with the optional Second Room System.\u003c\/p\u003e\n\n\u003ch3\u003eBuilt for round-the-clock commercial duty\u003c\/h3\u003e\n\u003cp\u003eThis is a purpose-built commercial line, not a residential generator pressed into business use. The boiler is designed for the demanding duty cycle of a revenue-generating facility — repeated daily sessions, fast recovery between guests, and the reliability an operator needs when the steam room is a booking driver. It carries Delta's \u003cstrong\u003eone-year commercial warranty\u003c\/strong\u003e for heavy commercial use.\u003c\/p\u003e\n\n\u003ch3\u003eA complete, turnkey package\u003c\/h3\u003e\n\u003cp\u003eEvery package ships ready to install: the boiler, a microprocessor digital command center for management, a user bypass control for clients, a room sensor, and a 360-degree steam head for even dispersion. The steam solenoid arrives pre-assembled to the generator. There is no separate parts list to chase — the working essentials are in the box.\u003c\/p\u003e\n\n\u003ch3\u003eProgrammable management controls\u003c\/h3\u003e\n\u003cp\u003eThe digital command center lets management program temperature ranges and an idle-setback schedule that can be tailored for each day of the week, holding the room ready during peak hours and conserving energy during off-peak. Clients adjust steam output within the preset range using the user bypass control. Controls operate from up to 100 feet from the generator (50-foot cables ship standard), so the boiler can live in a back-of-house equipment room.\u003c\/p\u003e\n\n\u003ch3\u003eSized and wired to your facility\u003c\/h3\u003e\n\u003cp\u003eThe package is offered in eight outputs from 9 to 48 kW and in 208V, 240V, or 480V, single- or three-phase, to match your building's electrical service. We size the output to your steam-room volume and confirm the voltage and phase your service supplies before anything is built — so the unit that ships is the one your space and your panel actually need.\u003c\/p\u003e\n\n\u003ch3\u003eMulti-room ready\u003c\/h3\u003e\n\u003cp\u003eWhen paired with the Delta Second Room System, one commercial boiler can serve two independent steam rooms, each with its own control — an efficient configuration for facilities running men's and women's rooms or multiple treatment suites from a single equipment room.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance \u0026amp; Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEight outputs from 9 kW to 48 kW, sizing rooms up to 2,000 cubic feet\u003c\/li\u003e\n  \u003cli\u003eEngineered for continuous, round-the-clock commercial operation\u003c\/li\u003e\n  \u003cli\u003e360-degree steam head for fast, even steam dispersion\u003c\/li\u003e\n  \u003cli\u003eRapid recovery between back-to-back commercial sessions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControls \u0026amp; Programming\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMicroprocessor digital command center for management programming\u003c\/li\u003e\n  \u003cli\u003eUser bypass control lets clients adjust steam within a preset range\u003c\/li\u003e\n  \u003cli\u003eIdle-setback scheduling, programmable individually for each day of the week\u003c\/li\u003e\n  \u003cli\u003eOperates from up to 100 feet from the generator (50-foot cables standard)\u003c\/li\u003e\n  \u003cli\u003eTwo relays prewired for an aromatherapy pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e208V, 240V, or 480V to match your building service\u003c\/li\u003e\n  \u003cli\u003eSingle-phase available up to 24 kW; three-phase across the full range\u003c\/li\u003e\n  \u003cli\u003eUnits 30 kW and above are three-phase only\u003c\/li\u003e\n  \u003cli\u003e480V configurations available from 12 kW up\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Room \u0026amp; Expansion\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRuns two independent steam rooms when paired with the Second Room System\u003c\/li\u003e\n  \u003cli\u003eCompatible with Delta aroma injection, blowdown valves, and generator stands\u003c\/li\u003e\n  \u003cli\u003eScales across a facility from a single back-of-house equipment room\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSizing Guide — Output to Room Volume\u003c\/h3\u003e\n\u003cp\u003eMeasure your steam enclosure (length x width x height, in feet) to find its cubic footage, then match it to the output below. For best performance, ceiling height should not exceed 8 feet (10 feet maximum). Tell us your room dimensions and electrical service and we'll confirm the exact configuration.\u003c\/p\u003e\n\u003cdiv style=\"border:1px solid #e3dccd;border-radius:8px;overflow:hidden;margin:16px 0;font-size:14px;\"\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:0.8fr 1.4fr 1.6fr 0.9fr;background:#1a2e24;color:#f9f6f2;font-weight:600;\"\u003e\n    \u003cdiv style=\"padding:11px 13px;\"\u003eOutput\u003c\/div\u003e\n    \u003cdiv style=\"padding:11px 13px;\"\u003eRoom Volume\u003c\/div\u003e\n    \u003cdiv style=\"padding:11px 13px;\"\u003eVoltage \/ Phase Available\u003c\/div\u003e\n    \u003cdiv style=\"padding:11px 13px;\"\u003eBreaker\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:0.8fr 1.4fr 1.6fr 0.9fr;border-top:1px solid #e3dccd;\"\u003e\n    \u003cdiv style=\"padding:11px 13px;font-weight:600;\"\u003e9 kW\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e0–400 cu ft\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e208 \/ 240V · 1 or 3-phase\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e30–60A\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:0.8fr 1.4fr 1.6fr 0.9fr;border-top:1px solid #e3dccd;background:#f9f6f2;\"\u003e\n    \u003cdiv style=\"padding:11px 13px;font-weight:600;\"\u003e12 kW\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e401–500 cu ft\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e208 \/ 240 \/ 480V · 1 or 3-phase\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e20–80A\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:0.8fr 1.4fr 1.6fr 0.9fr;border-top:1px solid #e3dccd;\"\u003e\n    \u003cdiv style=\"padding:11px 13px;font-weight:600;\"\u003e15 kW\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e501–620 cu ft\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e208 \/ 240 \/ 480V · 1 or 3-phase\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e25–90A\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:0.8fr 1.4fr 1.6fr 0.9fr;border-top:1px solid #e3dccd;background:#f9f6f2;\"\u003e\n    \u003cdiv style=\"padding:11px 13px;font-weight:600;\"\u003e18 kW\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e621–740 cu ft\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e208 \/ 240 \/ 480V · 1 or 3-phase\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e30–100A\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:0.8fr 1.4fr 1.6fr 0.9fr;border-top:1px solid #e3dccd;\"\u003e\n    \u003cdiv style=\"padding:11px 13px;font-weight:600;\"\u003e24 kW\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e741–1,000 cu ft\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e208 \/ 240 \/ 480V · 1 or 3-phase\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e40–150A\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:0.8fr 1.4fr 1.6fr 0.9fr;border-top:1px solid #e3dccd;background:#f9f6f2;\"\u003e\n    \u003cdiv style=\"padding:11px 13px;font-weight:600;\"\u003e30 kW\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e1,001–1,250 cu ft\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e208 \/ 240 \/ 480V · 3-phase\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e45–110A\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:0.8fr 1.4fr 1.6fr 0.9fr;border-top:1px solid #e3dccd;\"\u003e\n    \u003cdiv style=\"padding:11px 13px;font-weight:600;\"\u003e36 kW\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e1,251–1,500 cu ft\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e208 \/ 240 \/ 480V · 3-phase\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e60–125A\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:0.8fr 1.4fr 1.6fr 0.9fr;border-top:1px solid #e3dccd;background:#f9f6f2;\"\u003e\n    \u003cdiv style=\"padding:11px 13px;font-weight:600;\"\u003e48 kW\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e1,501–2,000 cu ft\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e240 \/ 480V · 3-phase\u003c\/div\u003e\n\u003cdiv style=\"padding:11px 13px;\"\u003e80–175A\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:13px;color:#5a5048;\"\u003eVoltage must match your local utility service. 90°C copper wire required for connection. Not sure which output fits? Tell us your room dimensions and we'll size it for you.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e9–24 kW units:\u003c\/strong\u003e 21\"L x 19\"W x 25\"H, approximately 200 lbs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e30–48 kW units:\u003c\/strong\u003e 39\"L x 22\"W x 28\"H, approximately 300 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVoltage: 208V, 240V, or 480V — must match local utility\u003c\/li\u003e\n  \u003cli\u003eSingle-phase available up to 24 kW; three-phase available across the full range\u003c\/li\u003e\n  \u003cli\u003eUnits 30 kW and above require three-phase service\u003c\/li\u003e\n  \u003cli\u003e480V configurations available from 12 kW up\u003c\/li\u003e\n  \u003cli\u003e90°C copper wire required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlumbing \u0026amp; Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eWater inlet: 1\/2\" NPT\u003c\/li\u003e\n  \u003cli\u003eSteam outlet: 3\/4\" NPT\u003c\/li\u003e\n  \u003cli\u003eRecommended ceiling height: 8 feet optimal, 10 feet maximum\u003c\/li\u003e\n  \u003cli\u003eGenerator mounts in a back-of-house equipment room up to 100 feet from the steam room\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControls \u0026amp; Steam Delivery\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMicroprocessor digital command center with day-of-week idle-setback scheduling\u003c\/li\u003e\n  \u003cli\u003eUser bypass control for client-side adjustment within preset limits\u003c\/li\u003e\n  \u003cli\u003eRoom sensor with 50-foot cable (control cabling supports up to 100 feet)\u003c\/li\u003e\n  \u003cli\u003e360-degree steam head dispersion\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat's in the Package\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDelta commercial steam boiler (output, voltage, and phase confirmed at quote)\u003c\/li\u003e\n  \u003cli\u003eMicroprocessor digital command center (management control) with cable\u003c\/li\u003e\n  \u003cli\u003eUser bypass control with 50-foot cable\u003c\/li\u003e\n  \u003cli\u003eRoom sensor with 50-foot cable\u003c\/li\u003e\n  \u003cli\u003e360-degree steam head\u003c\/li\u003e\n  \u003cli\u003eSteam solenoid, pre-assembled to the generator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequired for Operation (Not Included)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDedicated electrical circuit at the correct voltage and phase, installed by a licensed electrician\u003c\/li\u003e\n  \u003cli\u003eWater supply line (1\/2\" NPT inlet) and steam line (3\/4\" NPT outlet)\u003c\/li\u003e\n  \u003cli\u003eDrain connection for blowdown\u003c\/li\u003e\n  \u003cli\u003e90°C copper wire for the generator connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Add-Ons (Available at Quote)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSecond Room System — run two independent steam rooms from one boiler\u003c\/li\u003e\n  \u003cli\u003eAromatherapy pump and essential oils (boiler is prewired for aroma)\u003c\/li\u003e\n  \u003cli\u003eDigital auto blowdown valve and blowdown tank\u003c\/li\u003e\n  \u003cli\u003eGenerator stand\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eResources\u003c\/h3\u003e\n\u003cp\u003eDocumentation for the Delta Commercial Steam Boiler Package:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.deltafaucet.com\/SpecSheet\/DSP-S-5COM09%20Rev%20A.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCommercial Steam Generator Spec Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.deltafaucet.com\/sites\/delta\/files\/2023-08\/Steam_Generator_Sizing_Guide_Delta_Commercial.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCommercial Generator Sizing Guide (PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.deltafaucet.com\/MandI\/114415%20Rev%20F.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Maintenance Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eDelta (DFC) warrants that the parts, including electronic parts, of its steam bath generators with model numbers beginning with 5COM — which are intended solely for heavy commercial use — purchased from authorized Delta sellers and used in a commercial application will be free from defects in materials and workmanship for a period of one (1) year from the date the product is received by the original purchaser or their authorized representative. Delta will, at its option, repair or replace, free of charge, any part that proves defective in material or workmanship under normal installation, use, and service during the warranty period.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; code:\u003c\/strong\u003e Installation must be performed by a licensed electrician and plumber in accordance with local codes. Commercial installations are subject to your local Authority Having Jurisdiction (AHJ); requirements vary by municipality. Where steam rooms serve the public, ADA accessibility provisions may apply to the room and bench. Adequate ventilation and a proper drain are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReturns:\u003c\/strong\u003e Commercial steam boilers are made to order. Please \u003ca href=\"https:\/\/thesaunarepublic.com\/policies\/refund-policy\" target=\"_blank\" rel=\"noopener\"\u003ereview our return policy\u003c\/a\u003e, or contact our commercial team with any questions before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Buy from Sauna Republic\u003c\/h3\u003e\n\u003cp\u003eSauna Republic is an authorized Delta commercial dealer. We size the boiler to your room volume, confirm the voltage and phase your electrical service requires, and coordinate the package and any expansion components as one project with a single point of contact. Request a quote or call our commercial team at \u003cstrong\u003e(302) 273-0861\u003c\/strong\u003e, seven days a week.\u003c\/p\u003e","brand":"Delta","offers":[{"title":"Default Title","offer_id":48334460616858,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0689\/1536\/3994\/files\/delta-commercial-steam-boiler-package-generator-controls.jpg?v=1781604033","url":"https:\/\/thesaunarepublic.com\/products\/delta-commercial-steam-boiler-package","provider":"Sauna Republic","version":"1.0","type":"link"}