Elegible para HSA/FSA: su compra de bienestar podría calificar. Ahorre hasta un 35% con dinero antes de impuestos. Más información →

Bienestar a domicilio
Español

Hable con un especialista

Llámenos, envíenos un mensaje de texto o use el chat en vivo

● 7 días a la semana | 9 a. m.–5 p. m. EST
Solicitar precio

Calculadora del tamaño del calentador para sauna

Enter your sauna's interior dimensions, its construction and any glass or masonry surfaces. The calculator applies the published sizing rules of Harvia, HUUM and Saunum and recommends heaters whose room range covers your sauna.

Calculate Your Heater Size

Preferred Brand ?
?
Interior Dimensions
OR

Use the sauna maker's published interior volume if there is one. If you already adjusted a volume with our sizing guide, enter it here, keep the construction set to an insulated room and leave the surface fields blank.

Glass and Masonry Surfaces ?

Other surfaces are uninsulated glass, glass block, tile, brick, concrete or stone, such as windows or a bare concrete wall. Measure width × height in feet: a door 2 ft wide and 7 ft tall is 14 sq ft.

Electric sauna heater
Your Heater
Recommendation Awaits
Recommended Heater Size

Recommended Heaters for Your Sauna

Questions about your sauna, or a result near a heater's limit? Call us at (888) 833-2305 before you order.

How the Calculator Sizes a Heater

The calculator follows our sauna heater sizing guide, which is based on each manufacturer's published rules. It multiplies the interior length, width and height to get the room volume, adjusts that volume with each brand's rules, and compares the result with each heater's published minimum and maximum room volume. Each brand's rules apply only to that brand's heaters, so the adjusted volume can differ by brand.

Factor Harvia HUUM Saunum
Uninsulated glass, glass block, tile, brick, concrete or stone Add 3.9 cu ft per sq ft (1.2 m³ per m²) Add 3.3 cu ft per sq ft (1 m³ per m²) Add 3.9 cu ft per sq ft
Glass sauna door Counted with the surfaces above Counted with the surfaces above Not counted
Solid log walls Multiply the volume by 1.5 No multiplier in HUUM's current U.S. manuals No multiplier applied; call us to confirm
Ready-made barrel or outdoor sauna Start from the sauna maker's recommended heater size and confirm that the sauna's volume falls inside the heater's range. Where the maker publishes no recommendation, multiply the volume by 1.5.

When a room needs both adjustments, the calculator multiplies the volume first and then adds the glass and masonry allowance, as the sizing guide does. In each heater series, it recommends the smallest heater whose published range covers your adjusted volume, and it never recommends a heater for a room below the heater's published minimum. Harvia's manuals warn that when a heater is too large for the room, the air heats very quickly while the stones may not reach a sufficient temperature. If your adjusted volume is above one heater's range, the calculator moves to the next size in that series.

How to Measure Your Sauna

1. Measure the inside of the room: length, width and height, from the inside face of the paneling and from the floor to the ceiling. Exterior dimensions include the walls themselves and point to a larger heater than the room needs.

2. Choose the construction: an insulated room has insulation in the walls and ceiling, a vapor barrier and wood paneling. If one wall is bare concrete or block, keep the insulated setting and enter that wall's area as another surface rather than multiplying the whole room.

3. For a ready-made barrel or outdoor sauna: enter the maker's published interior volume as the total cubic feet, together with the maker's recommended heater size. SaunaLife, for example, recommends a 6 kW heater for its E7 barrel, which works out to about 170 cu ft inside.

4. Measure glass and masonry: measure each glass, glass block, tile, brick, concrete or stone surface, width × height in feet, and enter the glass door separately from the other surfaces, because Saunum does not count the sauna door. For a ready-made sauna, include the glass on the configuration you are ordering, such as halfmoon windows.

For the full method and worked examples, read our sauna heater sizing guide.

Electrical Requirements

Every heater in this calculator is a 240 V model. A 120-volt, 15-amp circuit delivers at most 1,800 W (120 × 15), so the heaters listed need 240 V. Current at 240 V equals the heater's watts divided by 240: a 6 kW heater draws 25 A, and a 9 kW heater draws 37.5 A.

If your building supplies 208 V rather than 240 V, the heater's 208 V rating applies, and it is lower: HUUM lists the DROP 6 at 4.5 kW and 142 to 248 cu ft on 208 V. Call us to size a 208 V installation.

Each manufacturer requires a professional electrical connection. Have a licensed electrician size the circuit to the installation manual and local code before you order.

Controllers and Stones

Most heaters in this calculator require a compatible controller, which we quote with the heater together with the stones. The Harvia KIP B models have built-in controls, and the Harvia Cilindro PC60, PC80 and PC90 are operated with switches on the heater; for these heaters, we quote the stones with the heater. Saunum heaters require a compatible Saunum controller.

Electric Sauna Heater Brands We Carry

Harvia

The Harvia heaters in this calculator cover rooms from 100 to 1,000 cu ft: the KIP (4.5 to 8 kW), with built-in controls (KIP B) or for a separate controller (KIP W); the Spirit SP60E and SP80E; the Cilindro (6 to 10.5 kW), operated with switches on the heater (PC60, PC80 and PC90) or with a separate controller (PC60E to PC110E); the Virta Combi (8 to 10.5 kW), which adds a built-in steamer; and the Club (10 to 15 kW) for rooms of 390 to 1,000 cu ft. Room ranges come from Harvia's product pages for the 240 V models.

Shop All Harvia Heaters

HUUM

The HUUM heaters in this calculator come in four series: the DROP (4.5 to 9 kW), the CLIFF (3.5 to 10.5 kW), the HIVE Mini (6 to 10.5 kW) and the bench-embeddable CORE (6.5 to 10.5 kW). The calculator uses the room ranges in HUUM's 2026 U.S. manuals at 240 V, from a minimum of 106 cu ft for the smallest models to a maximum of 566 cu ft for the 10.5 kW models. Every HUUM heater requires a compatible controller, quoted with the heater together with the stones.

Shop All HUUM Heaters

Saunum

The Saunum heaters in this calculator are the AIR 5 (4.8 kW) and AIR 7 (6.4 kW), which Saunum describes as using a patented mixing system that captures the hot steam rising under the ceiling, mixes it with cooler air from the floor and directs the milder steam back evenly. The room range differs by finish: 106 to 212 cu ft for the AIR 5 and 212 to 282 cu ft for the AIR 7 in Stainless Steel, and 106 to 177 cu ft and 177 to 247 cu ft in Nordic Black. Saunum heaters require a compatible Saunum controller, quoted with the heater together with the stones.

Shop All Saunum Heaters

FAQ

It multiplies your sauna's interior length, width and height to get the room volume, applies each brand's published adjustments for log walls, ready-made barrel and outdoor saunas, and uninsulated glass, tile, brick, concrete or stone, and then recommends, in each heater series, the smallest heater whose published room range covers the adjusted volume. For an insulated 6 × 5 × 7 ft room with a 14 sq ft glass door, Harvia's rule gives about 265 cu ft, inside the 170 to 300 cu ft range of the Harvia KIP 6 kW models.
Each brand publishes its own adjustments. Harvia adds 1.2 m³ per m² of uninsulated surface, about 3.9 cu ft per sq ft, and multiplies the volume of a solid log room by 1.5. HUUM's current U.S. manuals add 1 m³ per m², about 3.3 cu ft per sq ft, and give no log-wall multiplier. Saunum adds 3.9 cu ft per sq ft but does not count the sauna door. For a 6 × 5 × 7 ft room with a 14 sq ft glass door, that gives about 265 cu ft for Harvia, 256 cu ft for HUUM and 210 cu ft for Saunum.
Start from the heater size the sauna maker recommends and confirm that the sauna's interior volume falls inside the heater's range. SaunaLife recommends a 6 kW heater for its E7 barrel, as our listing notes. Its interior works out to about 170 cu ft, and the 1.5× barrel adjustment, used as a cross-check, brings that to about 255 cu ft, inside the ranges of the HUUM DROP 6 (177 to 318 cu ft) and the Harvia KIP 6 kW models (170 to 300 cu ft). Where the maker publishes no recommendation, the calculator multiplies the volume by 1.5. Include the glass on the configuration you are ordering, such as halfmoon windows.
Neither. Choose a heater whose published range covers your adjusted volume. Harvia's manuals explain why both extremes fail: an oversized heater heats the air very quickly while the stones may not reach a sufficient temperature, and an undersized heater heats the room slowly, and water thrown on its stones only cools them. If your adjusted volume is above one heater's range, move to the next size.
Not with any heater in this calculator. A 120-volt, 15-amp circuit delivers at most 1,800 W, so the heaters listed need 240 V. Plan for a 240 V circuit connected by a licensed electrician. If your building supplies 208 V, call us, because heater ratings are lower on 208 V.
Yes. If you have worked through the steps in our sauna heater sizing guide, enter the adjusted total in the total cubic feet field, keep the construction set to an insulated room and leave the surface fields blank, so the calculator does not apply the adjustments twice. The calculator then lists the heaters whose published range covers that total.
Most heaters in this calculator require a compatible controller, which we quote with the heater together with the stones. The Harvia KIP B models have built-in controls, and the Harvia Cilindro PC60, PC80 and PC90 are operated with switches on the heater; for these heaters, we quote the stones with the heater.

Ready to Choose Your Heater?

Send us your room dimensions and the heater you are considering. We will quote the heater together with the stones and, where one is required, a compatible controller.